Description
Technical Specifications
- Supported Subcard:
- HSIC-X08S000 (Part Number: 02314VYH)
- Supported Fan:
- FAN-031A-B (Part Number: 02352CAB, two delivered by default)
- Supported Power Modules:
- 180 W AC Power Module (Part Number: 02131754)
- 240 W DC Power Module (Part Number: 02314VUJ)
- 400 W DC Power Module (Part Number: 02314VUG)
- 600 W AC Power Module (Part Number: 02313BUS, one delivered by default)
- Switching Capacity: 1568 Gbit/s
- Packet Forwarding Rate: 1167 Mpps
- GE RJ45 Ports:
- 24 × GE RJ45 (1G/100M/10M)
- 10G SFP+ Ports:
- 16 × 10GE SFP+ (10G/2.5G/1G/100M)
- 25G SFP28 Ports:
- 8 × 25GE SFP28 (25G/10G/2.5G/1G)
- 100G QSFP28 Ports:
- 2 × 100GE QSFP28 (100G/40G)
- iStack: Supports up to 9 switches of the same series in a stack
- Number of Card Slots: 1
- Number of Power Slots: 2
- Certification:
- EMC certification
- Safety certification
- Manufacturing certification
- Chassis Material: Metal
- Dimensions (H × W × D):
- Basic dimensions (excluding the parts protruding from the body): 43.6 mm × 442.0 mm × 420.0 mm (1.72 in. × 17.40 in. × 16.54 in.)
- Maximum dimensions (depth measured from front-panel ports to the parts protruding from the rear panel): 43.6 mm × 442.0 mm × 454.0 mm (1.72 in. × 17.40 in. × 17.87 in.)
- With packaging: 145.0 mm × 650.0 mm × 550.0 mm (5.71 in. × 25.59 in. × 21.65 in.)
- Installation Type: Rack mounting / Desk mounting
- Weight: 6.31 kg (13.91 lb) without packaging / 8.76 kg (19.31 lb) with packaging
- Static Power Consumption: 77 W
- Typical Power Consumption:
- 30% traffic under the ATIS standard with dual power modules:
- 122 W (with two 180 W AC power modules)
- 118 W (with two 240 W DC power modules)
- Maximum Power Consumption:
- 100% traffic under the ATIS standard with dual power modules:
- 127 W (with two 180 W AC power modules)
- 123 W (with two 240 W DC power modules)
- Number of Fan Modules: 2
- Redundant Power Supply:
- 1+1
- Pluggable AC and DC power modules can be used together on the same device.
- Power modules with fans and power modules without fans cannot be installed on the same device.
- Long-Term Operating Temperature:
- –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.)
- Long-Term Operating Relative Humidity [RH]: 5% RH to 95% RH, non-condensing
- Power Supply Mode: Pluggable power supply
- Input Voltage Range:
- AC input: 90 V AC to 290 V AC; 45 Hz to 66 Hz
- High-voltage DC input: 190 V DC to 290 V DC
- DC input: –38.4 V DC to –72 V DC
- Power Supply Surge Protection:
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
- Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
- Types of Fans: Pluggable
- Heat Dissipation Mode: Air cooling for heat dissipation with intelligent fan speed adjustment
- Airflow Direction: Air intake from the front and right, with air exhaust from the rear